Energy Meter Testing Equipment

Ensures to validate the accuracy, reliability, and compliance of electricity meters used in residential, commercial, and industrial applications as per IEC 62052, IEC 62053, and IS 13779 covering both active and reactive energy measurement.

Short-Time-Over-Current-Test-Equipment
Short Time Over Current Test Equipment suitable for testing the influence of Short-time over-current on all types of energy meters.

Short Time Over Current Tester

The Short-time Over-current Test Equipment is suitable for testing the influence of Short-time over-current on all types of energy meters that should confirm to or exceed the requirements of national and international standards. This test is described in various standards such as IEC 62053, IS 13779 etc.

As per CEI / IEC 62053, short-time over-current shall not damage the meter. The meter shall perform correctly when back to its initial working condition and the variation of error shall not exceed particular values specified on basis of the class of the energy meter.

STOC is appropriate for use by test laboratories, research & development centres & manufacturers for conformity assessment services, research and type testing.

Salient Features

Specification

Variants & Customization

Following Variants are available:

  1. Short Time Over Current Test Setup (STOC-01)- 50 to 3000A
  2. Short Time Over Current Test Setup (STOC-02)- 50 to 5000A
  3. Short Time Over Current Test Setup (STOC-03)- 100 to 10000A

Application

Short-time Overcurrent Test Equipment is used to measure and analyze the influence of short-time overcurrents on energy meter.

Voltage Dip Measurement for Energy Meters

The setup is used to measure and analyse the influence of supply voltage on energy meter. This test is described in various standards for energy meters such as IS 13779, IEC 62053 etc.

The test shall be carried out under the following conditions as per IEC 62053-21, IS 13779 clauses 12.7.2:

  1. Meter in operating condition
  2. Voltage and auxiliary circuits energized with reference voltage
  3. Without any current in the current circuits.
 
 The standard suggests three tests that are pre-programmed:
  • Voltage Interruption of 100 %: (When test 1 is selected)
  • Voltage Interruption of 100 %: (When Test 2 is selected
  • Voltage Dips of 50 %: (When Test 3 is selected)
Voltage-Dip-Measurement-for -Energy-Meters
Voltage Dip Measurement for Energy Meter

Salient Features

Variants

The product is mostly offered as a standard issue; however, we can customize it further if required.

Specification

Application

The test kit is used to test the influence of supply dip on energy meter, after which the meter is tested for usual tests and the results are compared with previous one

Heat-Pump-Unit-Test-Panel

Jaguar Heat Pump

The SCR make Jaguar Heat Pump Unit Test Bench is designed for final testing, quality assurance, and compliance verification of air conditioning units. It ensures reliable validation of electrical safety parameters such as earth bond, insulation resistance, high voltage withstand, and earth leakage current. 

Additionally, it evaluates operational performance including current, wattage, RPM, and compressor pressure.

This test bench will have only PC modes of operation. All the tests will be carried out sequentially and the Data will be displayed and stored on PC. Lab VIEW based software and Siemens make PLC as an Interface module will be used to control the whole sequence. Option will be given for selection of test. If in different models of AC Tests are different, then that can be done by selecting the type no. (model) of AC

Salient Features

Specification

Test Procedure

Application

The Jaguar Heat Pump Unit Test Bench is Ideal for manufacturing lines, service centers, and R&D labs, the system supports model-specific test configurations and automated test sequencing for consistent and efficient evaluation.

Variants

PC-Based-Testing-Setup-for-Optyma-Plus-Controller-Based-Model

PC Based Testing Setup for Optyma Plus (Controller Based) Model 

Comprises of Variable Voltage Source – 3 Phase adjustable between 0 – 550V @4Amp. The voltage and current will be displayed on computer screen through transmitter. The output of the transducer will be given to DAQ which will degitise the signal give it to PC through interface

Test-Setup-for-Air-Conditioner

Test Setup for Air Conditioner or domestic electrical appliances is designed to carry out the tests as per the IS 302. It broadly consist of following tests.

1. Earth Contact Resistance Test

2. High Voltage Test

3. Insulation Test

Automatic Test Setup for Air Conditioners

SCR Elektroniks offers a robust, PC-controlled test setup for air conditioners, engineered to validate both electrical safety and functional performance in compliance with industry standards. The system is built around a LabVIEW-based software

Automatic-Safety-Test-Panel-for-1Phase-or-3Phase-Condensing-Unit

Table of Contents

Get A Quote